close
Arrange a Survey

energiSava® 325

Ultra Efficient Whole House Heat Recovery System

Ideal for medium to large sized dwellings, the energiSava® 325 brings together exceptional performance and efficiency within a compact and patented design. Highly effective at reducing indoor pollutants and improving indoor air quality, the unit runs continuously to provide optimum ventilation all year round.

 

Key Features

  • Energy Efficient
    Energy Efficient

    Delivering up to 91% thermal efficiency.

  • Frost Protection
    Frost Protection

    An intelligent frost protection system prevents the heat exchange from freezing when cold outside.

  • Mechanical Summer Bypass
    Mechanical Summer Bypass

    Benefiting from a temperature controlled integral mechanical summer by-pass as standard.

  • Humidity Sensor
    Humidity Sensor

    Incorporates integral humidity sensor which monitors relative humidity.

  • 2 Year Warranty
    2 Year Warranty

    High quality products for peace of mind, saving time, money and hassle.

About

Exceptional Performance

Independently tested by the BRE and recognized in the UK Product Characteristics Database in SAP Appendix Q, the energiSava® 325 is suitable for properties with kitchen plus 6 additional wet rooms, delivering maximum airflow of 93l/s at 100Pa with a low Specific Fan Power down to 0.60 W/l/s and high thermal efficiency of up to 91%.

Ease of Installation

With a compact, lightweight design for easy handling, the energiSava® 325 offers innovative features for hassle-free installation. With a quick fit mounting bracket and easy spigots connecting directly to 150mm ducting without the need for adaptors, the unit incorporates independent fan adjustment for straightforward commissioning.

Intelligent Controls

The energiSava® 325 comes with an LED status indicator displaying the mode of operation that the unit is operating in, including a filter and fault indicator. The Boost Alert function on the display is a timer designed to prevent the unit from being accidentally left in Boost mode for long periods of time. Once the unit is placed in Boost the timer is activated and after 2 hours the LED on the display will start to flash, notifying the user to switch off the Boost.

Summer Bypass

The energiSava® 325 incorporates a fully automatic 100 airflow diverting Summer Bypass to operate during hot periods. This routes the pre-heated extracted air around the heat cell and out to atmosphere, allowing the cooler, fresh air to be supplied directly into the property.

A Summer Kickup Mode is also available which allows both the supply and extract fans to operate at full speed whenever the Summer Bypass is activated. During cold weather, the automatic Frost Protection reduces the supply ventilation rate to prevent ice buildup within the heat cell.

Integral Humidity Sensor

The unit runs continuously 24 hours a day and incorporates an integral humidity sensor which monitors the relative humidity (RH) of the extracted air. When the relative humidity rises above the set trigger point, variable from 55RH to 85 RH, it increases the airflow proportionately to ensure minimum noise levels.

Product Codes
Product Name
Product Description
ESAVA325
Standard, Summer Bypass and Humidity Sensor
ESAVA325-L
Standard, Summer Bypass and Humidity Sensor - Left Hand Version
SWHT-STATUS
Hard-wired LED Status Indicator
Product Specification

Product Dimensions

Performance Curve

Question & Answers

How does MVHR work?

Mechanical Ventilation with Heat Recovery works to ventilate the whole property by extracting air from wet rooms (kitchen, bathroom, toilet, utility’s etc.), this extraction is passed through a central unit to recover as much heat from the air as possible before pushing moisture outside. At the same time fresh air is pulled from outside passed through the central unit to warm up incoming air and filtering it before supplying air to habitable rooms (bedrooms, Livingroom’s, dining rooms etc). These two air flows do not physically mix.

Does ducting require to be insulated?

Any ducting passing through a unheated area will require to be insulated. Ducting connecting the unit to/from atmosphere will require insulating.

How often does a MVHR need servicing?

Any MVHR unit will need the filters checking at least every 6 months. It may be at 12-18 months they will need replacing. This time scale will depend largely on the environment and speed of the unit. Ideally at a 5-year period the system should be checked to confirm operation is to standard.

MVHR is noisy, running fast:

This can be dependent on what MVHR unit you have. To ensure minimal noise units must be installed as per the design using proprietary components. Systems must also be commissioned and set up correctly to ensure performance. Some units may have humidity sensors that automatically increase air flow speed to control humidity levels, therefore at times of high humidity the system will be working harder. Some units may also automatically increase in speed as filters become clogged up.

Can I turn the unit off?

It is not recommended to turn the unit off, other than for maintenance. Turning the unit off can damage the unit and invalidate its warranty. Also, by turning the unit off and stopping air movement in a property can lead to other issues, condensation, mould, smells, etc...
Arrange a Survey

We have local experts across the UK who can offer free advice and recommend the right products for your property.

Request a Brochure

Want to find out more about our products and service? Request a free brochure and we'll send one out in the post to you.

Find a Local Expert

We have local ventilation specialists throughout the United Kingdom who are able to help you with your problems.